1 inverter mode status messages, Operation, Inverting settings/info – Magnum Energy ME-RTR Router User Manual
Page 64: Figure 5-4, empty, Figure 5-3.3, all ports screen status messages

©
2014 Magnum Energy, Inc.
Page 56
Operation
Info: Whenever referencing “inverter/charger” in this section, please note it is referring
to all paralleled stacked inverter/chargers, not individual inverter/chargers.
FAULT
PWR
CHG
INV
MS4024PAE Inverter
Low Battery
20.0VDC 0ADC
P1 INV Home
Solid
FAULT LED
PORT Screen
Device Menu Heading
Device Connected
Device Status
Device Info
Figure 5-3.2, Individual PORT Screen
Status Messages
FAULT
PWR
CHG
INV
Inverting
Settings/Info...
Inverting appears on the LCD. The PWR (green) and
INV (green) LEDs are on solid. The FAULT (red) and CHG
LEDs are off.
There are three modes of operation for the inverter/charger system:
• Inverter Mode • Charger Mode • Fault Mode
5.3.1
Inverter Mode Status Messages
There are several Inverter mode messages. View the top line of the LCD display and the
corresponding message in this section to identify and understand the particular Inverter mode.
• Inverting (Invert) – The inverter is providing AC voltage on its output by inverting power
from the batteries.
Figure 5-5, Inverting Mode
Figure 5-3.1, SYSTEM Screen Status Messages
FAULT
PWR
CHG
INV
Over Temperature
Gen off
20.0VDC 0ADC
ALL System Home
All
Ports
System Home
Menu
System
Current
Blinking
FAULT LED
Accessory Status
(first port )
System
Status
System
Voltage
Note: If a BMK is installed: the
system voltage and system current
values are BMK readings.
If a BMK is not installed: the
system voltage is the voltage of
the master inverter, and the
system current is the sum of the
currents of all inverters connected
in parallel.
Empty appears on the LCD. The PWR (green) and INV
(green) LEDs are on solid. The FAULT (red) and CHG
LEDs are off.
Figure 5-4, Empty
• Empty – No device is connected to the router port.
Note: This status differs from a “No Inverter Found!” fault status. Power is present, but no
information is being received from the router port.
FAULT
PWR
CHG
INV
1 Empty 2 Empty
3 INV 4 Empty
5 Empty 6 Empty
ALL Port Home
FAULT
PWR
CHG
INV
1 Low Bat 2 Empty
3 Empty 4 Empty
5 Empty 6 Empty
ALL Port Home
Inverter status alternates with other inverter info
Note: Statuses abbreviated on All PORTs screens
Blinking
FAULT LED
Figure 5-3.3, All PORTs Screen Status
Messages