2 charger mode status messages – Magnum Energy ME-RTR Router User Manual

Page 65

background image

Page 57

©

2014 Magnum Energy, Inc.

Operation

FAULT

PWR

CHG

INV

Off

Settings/Info...

Off appears on the LCD. All LEDs are off.

Figure 5-7, Off Mode

• Off

– This message tells you that there is no AC available on the inverter’s AC output. The

inverter function is OFF and there is no utility or generator AC power sensed on its input.

Figure 5-8, Searching Mode

Searching appears on the LCD. The PWR (green) LED

is on solid and the INV (green) LED fl ashes. The FAULT

(red) and CHG (green) LEDs are off.

• Searching

(Search)

– The inverter is in Search mode—the AC loads on the inverter output

are less than the SETUP button’s 02A Search Watts setting. The Search mode function reduces the

inverter draw from the battery, and may be turned off at any time if you want full inverter output.

FAULT

PWR

CHG

INV

Searching

Settings/Info...

FAULT

PWR

CHG

INV

Unknown Mode ##

Settings/Info...

Unknown Mode ## appears on the LCD. The PWR

(green) LED is on solid and the INV (green) LED fl ashes.

The FAULT (red) and CHG (green) LEDs are off.

Figure 5-9, Unknown Mode ##

• Unknown Mode ## (Mode ##) – This status message displays when the inverter/charger

has sent a fault code that cannot be determined by the router.

Remedy: Call the Technical Support department at Magnum Energy (425-353-8833)

for assistance in determining and understanding the actual fault status.

5.3.2

Charger Mode Status Messages

When AC power (utility or generator) is connected to the inverter/charger it monitors the AC input

for acceptable voltage. Once AC input is accepted, the AC transfer relay (within inverter) closes

and Charge mode begins. View the top line of the LCD display and the corresponding message in

this section to identify and understand the particular Charge mode that displays.

Info: The AC input becomes acceptable once a minimum 10-second delay passes, the

voltage is greater than the SETUP button’s 03B Low VAC Dropout setting, and there is

no CTRL: AC In Control menu setting that is actively preventing the AC from connecting.

Inverter Standby appears on the LCD. The INV (green)

LED is on solid. All other LEDs are off.

FAULT

PWR

CHG

INV

Inverter Standby

Settings/Info...

• Inverter Standby (Inv Stby) The inverter is on, but not actively providing power. However,

it is monitoring the power requirement of the parallel system to determine when to activate and

provide power to assist the master inverter.

Figure 5-6, Inverter Standby Mode