Movvel> working registers, Rdamulti, Revision – Yaskawa MP2000 User Manual
Page 98

TECHNICAL NOTE
This table outlines the data in the eight registers used by the function block. There is
not usually any need for the user to access any of these bits directly.
Register No.
Type
Name
Description
AW00000
Bit 0
IN
execute
EXECUTE
input (XB000000)
Bit 1
Working
positive
Positive direction mode is selected
Bit 2
Working
negative
Negative direction mode is selected
Bit 3
Working
inrng2
Verifies DIRECTIO input is in range.
Bit 4
Working
inerr
Goes High if inrng2 does not go high when block is executed.
Bit 5
Working
currnet
Current direction mode is selected
Bit 6
Working
movepos
If current direction mode is selected and axis is moving in a
positive direction.
Bit 7
OUT
running
Directly controls YB000000 (RUNNING Output)
Bit
8
Reserve.
Bit 9
OUT
error
Directly controls YB000002 (ERROR Output)
Bit A
Working
oneshotA
Reserved
Bit B
Working
firstPass
One shot coil for initializing axis. Goes High with rising edge of
EXECUTE input.
Bit C
Working
inspeed
Velocity selected is out of range.
Bit D
Reserved
Bit E
Working
moverr
Latches on when current direction is called for and axis is not
moving
Bit F
Working
direrror
SVON block did not allow this direction for the move
AL00002
Working
Speed set to RDA and controller.
AW00004
Bit 0
Working
oneshot10
Reserved
Bit 1
Working
commanderr
Rising Edge indicates another block took control.
Bit 2
Working
errStop
Goes high if servo faults out while running
Bit 3
Working
onepass
One shot coil for initiating axis data
Bit 4
Working
inRngAxis
Goes high for one scan if Axis input is in range.
Bit 5
Working
axisInErr
Goes high for one scan if Axis input is out of range.
Bit 6
Working
oneshot46
Reserved.
Bit 7
Working
closepass
Internal use for the next execution.
Bit 8
Working
atSpd
Directly controls YB000001(ATVEL Output)
Bit A
Working
oneshot4A
Reserved.
Bit D
Working
oneshot4D
Reserved.
AW00005
Working
rdaMulti
Value for address offset to locate proper RDA
AW00006
Working
revision
Revision Level of the function block.
File: MP2000_IndividualFunctionDocument_RevC 98/168