Alrmrst> block error condition, Alrmrst> working registers – Yaskawa MP2000 User Manual
Page 124

TECHNICAL NOTE
The following table outlines several situations that may cause an error, and will turn on 
the blocks “Error” output bit. 
Internal Fault Bit
Cause
Note
axisout 
AB00000C 
Axis specified by 
user is out of 
range 
Valid range is 1 to 16. Will not write to 
RDA 
Time-out 
AB00000D 
Alarm condition did 
not clear within 
default timeout 
(500msec). 
Alarm condition may still exist. Will not 
write to RDA. May need to cycle power 
on controller and servopacks to clear the 
error, set-up parameter may be out of 
range, or hardware failure may exist. 
 
 
This table outlines the data in the four registers used by the Alarm Reset function block. 
There is not usually any need for the user to access any of these bits directly. 
Register No
TYPE
Name
Description
AW00000
Bit 0
IN
EXECUTE
EXECUTE input (XB000000)
Bit 8
OUT
DONE
DONE output (YB000000)
Bit 9
OUT
ERROR
ERROR output (YB000001)
Bit A
Working
oneshotA
Rising edge
Bit B
Working
firstPass
Initialize block
Bit C
Working
axisout
Indicates axis input is out of range
Bit D
Working
Time-out
Indicates that the alarm did not reset within a specified 
(500msec default) timeout period. 
AW00001
Working
Counter
Timer for pausing post reset
AW00002
Working
rdaMult
Value for address offset to locate proper RDA
AW00003
Working
Revision
Revision level for block
 
 
 
 
 
 
 
 
 
 
File: MP2000_IndividualFunctionDocument_RevC 124/168 
Doc Number: eng.MCD.05.101 
11/17/2005