Moveabs> block error condition, Moveabs> working register – Yaskawa MP2000 User Manual
Page 85

TECHNICAL NOTE
The following table outlines several situations that may cause an error, and will turn on
the blocks “Error” output bit. The block “Error” output will cleared if the EXECUTE bit
goes low.
Internal error bit
Cause
Attention
inRng
AB000005
Direction input set
out of range
The internal register is reverse logic, it
must be ON to indicate the direction input
is within valid range. Sets RDA Error ID
(MW3**81) bit 3 on if error state exists.
errStop
AB000143
Servo Error while
in motion
If the error occurs in the servo while the
function is operating, this relay becomes
on. Bit B of RDA Error ID(MW3**81) is
turned on.
axisInErr
AB00014A
The axis number
entered on the
input is not an
acceptable value
The function blocks can only control 1 to
16 axis. Any value greater or smaller then
this will cause an error. This does not set
the RDA Error ID.
commanderr
Another block took
control of the axis.
If the block looses control of the axis while
running an error will occur. This does not
set the RDA Error ID.
AB00000E
direrror
AB00000F
The direction
commanded to
travel is disabled
from the SVON.
The SVON block must be used and have
the direction commanded enabled. Sets
RDA Error ID (MW3**81) bit 4 on if error
state exists.
This table outlines the data in the eighteen registers used by the function block. There
is not usually any need for the user to access any of these bits directly.
Register No
TYPE
Name
Content
AW00000
Bit 0
IN
execute
Enable
input (XB000000)
Bit 1
IN
shortest
Shortest direction mode is selected
Bit 2
Working
posDir
Positive direction mode is selected
Bit 3
Working
movback
If shortest path is selected and reverse direction is shortest
Bit 4
Working
movfor
If shortest path is selected and positive direction is shortest
Bit 5
Working
inRng
The input of DIRECTIO and POSITION is outside ranges.
Bit 6
Working
negDir
Negative direction mode is selected
Bit 7
OUT
running
Directly controls YB000000 (Running Output)
Bit 8
OUT
complete
Directly controls YB000001 (Done Output)
Bit 9
OUT
error
Directly controls YB000002 (Error Output)
Bit A
Working
oneshotA
Reserved.
Bit B
Working
firstPass
One shot coil for initiating axis
Bit C
Working
correntDir
Current direction mode is selected
Bit D
Working
movingneg
If in current direction mode and axis is currently going in
negative direction.
Bit E
Working
commanderr
Rising Edge indicates another block took control.
Bit F
Working
direrror
Indicates direction commanded is not enabled.
File: MP2000_IndividualFunctionDocument_RevC 85/168
Doc Number: eng.MCD.05.101
11/17/2005