Movinc> working register, Startpos, Distgone – Yaskawa MP2000 User Manual
Page 94: Rdamulti, Revision

TECHNICAL NOTE
This table outlines the data of the register of eight that the function block use is done.
The user is, and there is not a necessity and either is usually no what directly accessed
any of these bits.
Register No
TYPE
Name
Content
AW00000
Bit 0
IN
execute
EXECUTE
input (XB000000)
Bit 1
IN
onepass
One shot on rising edge of EXECUTE input to set axis data.
Bit 2
Working
axisInErr
Latches high if Axis input is out of range.
Bit 3
Working
oneshot3
Reserved
Bit 4
Working
inrngaxis
Goes high for one scan if Axis input is in range.
Bit 5
Working
oneshot5
Reserved
Bit 6
Working
completeSet
Reserved
Bit 7
OUT
running
Directly controls YB000000 (RUNNING Output)
Bit 8
OUT
complete
Directly controls YB000001 (DONE Output)
Bit 9
OUT
error
Directly controls YB000002 (EEROR Output)
Bit A
Working
oneshotA
Reserved
Bit B
Working
firstPass
One shot on rising edge of EXECUTE input to initialize axis.
Bit C
Working
oneshotC
Reserved
Bit D
Working
errStop
Indicates axis faulted and is commanded to move.
Bit E
Working
commanderr
Rising Edge indicates another block took control.
Bit F
Working
direrror
Indicates direction commanded is not enabled.
AW00001
Bit 0
Working
oneshot10
Reserved
Bit 1
Working
closepath
Internal use for the next execution.
Bit 2
Working
second_Pass
Reserved
Bit 6
Working
position_Mode
Confirmation of positioning mode.
Bit 7
Working
move_Done
Confirmation of positioning completed.
Bit D
Working
oneshot1D
Reserved
AL00002
Working
startpos
Position of axis at start of move.
AL00004
Working
distGone
Directly controls YL000001 (DISTGONE Output)
AW00006
Working
rdaMulti
Value for address offset to locate proper RDA
AW00007
Working
revision
Revision Level of the function block.
File: MP2000_IndividualFunctionDocument_RevC 94/168