Slaveoff> working register, Startmaster, Desired_shift – Yaskawa MP2000 User Manual
Page 102: Revision

TECHNICAL NOTE
This table outlines the data in the eight registers used by the Home function block.
There is not usually any need for the user to access any of these bits directly.
Register No
TYPE
Name
Content
AW00000
Bit 0
IN
execute
EXECUTE
input (XB000000)
Bit 1
IN
distmode
DST-TIME
input (XB000001)
Bit 3
Working
zerodiv
If duration is set to zero for one scan change, this turns on for
one scan (one-shot)
Bit 6
Working
distShft_init
High for one scan to initialize for master position shifting if first
pass is high and DISTMODE is high. To initialize for master
position control of offset.
Bit 7
OUT
running
Directly controls YB000000 (RUNNING Output)
Bit 8
OUT
complete
Directly controls YB000001 (DONE Output)
Bit 9
OUT
error
Directly controls YB000002 (ERROR Output)
Bit A
Working
oneshotA
Resered
Bit B
Working
firstPass
High for first scan of execute being high
Bit D
Working
timeshft_init
One shot coil for resetting outputs. Controlled by (AB00000A)
Bit E
Working
inrng1
High for one scan to initialize for time based shifting if first pass
is high and DISTMODE is low.
AW00001
Working
scans_per_shif
t
Number of scans needed to complete a time based
shift.
AW00002
Working
iStore
Pass through value for i.
AW00003
Working
mstrSlv
MSTSLAVE input (XW000001) – 1.
AL00004
Working
maxShift_scan
Maximum counts allowed to shift per scan on a
time based scan.
AL00006
Working
posLAUlim
Positive value of maxShift_scan
AL00008
Working
negLAUlim
Negative value of maxShift_scan
AL00010
Working
total_Shifted
Amount Slave Offset has changed during the
execution of the block.
AL00012
Working
shiftvalue
Value to change the RDA (ML56**6) Slave offset
for that scan.
AL00014
Working
startmaster
Value of Master counter at start of block
(AB0006=ON) for position based move.
AL00018
Working
desired_shift
Total amount needed to be shifted for the master
position mode.
AL00020
Working
timemod
Reserved.
AW00022
Working
Revision
Revision Level of the function block.
File: MP2000_IndividualFunctionDocument_RevC 102/168
Doc Number: eng.MCD.05.101
11/17/2005