Camscale> block fault condition – Yaskawa MP2000 User Manual
Page 28

TECHNICAL NOTE
File: MP2000_IndividualFunctionDocument_RevC 28/168 
Doc Number: 
EF.MCD.05.101
11/17/2005
Input Registers 
The following registers are used as inputs to the function block. They select the options 
and define the parameters that the user needs to make the function work as necessary. 
INPUT
TYPE
Content
Range and state
EXECUTE
Bit
Block enable – Block cannot 
execute unless this is TRUE. 
Rising edge initiates block 
TRUE – Block enable 
FALSE – Block disable, set all 
outputs to zero and off 
DST-TIME
Bit
Selects master or time for 
offset duration 
TRUE – Master position is used 
for duration 
FALSE – Time is used for 
duration 
M-S-PAIR
Word
Defines which Master-Slave 
pair is updated in RDA 
1 to 10 value. Any other value 
will cause the error output to go 
on 
DURATION
Long
Depends on DST-TIME 
setting. 
Either time in msec or distance 
master must travel in counts to 
complete change in offset. 
-2147483648 to 2147483647 If 
in time mode no negative 
numbers are allowed. 
SCALE
Long
Absolute scale to be applied to 
the slave. RDA will hold 
current scale level. (RDA offset 
is ML56**8) 
2147483648~2147483647
DATA23W
Address Address of the first working
register.
Twenty-three words of register 
space are used by this function. 
The following tables might cause the error, and outline some situations. If the 
EXECUTE input bit is turned off, the value is cleared. 
Internal Fault Bit
Cause
Note
inrng1 
AB00000E 
MSTRSLV value 
out of range 
Inrng1 must be high if execute is on or an 
error will occur. MSTRSLV must have a 
value from one to ten for this bit to be on. 
Sets RDA Error ID (MW3**81) bit 3. 