Aenc_rst> input and output register map, Output, Type – Yaskawa MP2000 User Manual
Page 118: Description, Running, Done, Error, Execute, Axis, Data05w

TECHNICAL NOTE
• If EXECUTE has been turned ON, But the Absolute encoder rest operation does
not complete within 5 seconds, ERROR output bit will turn ON. For the time 
between the EXECUTE ON and the ERROR output bit turns ON, the RUNNING 
output bit will be ON 
• Five words are used as working registers for this function, starting at the address
in Data05W
 
 
Output Registers 
The following registers are used as outputs from the function block. They can be 
monitored by the LadderWorks program to check the execution of the function. 
 
Output Type 
Description
RUNNING
Bit
High while block has control and Absolute 
Encoder Reset Procedure is in process 
DONE
Bit
Indicates the Absolute Encoder Reset 
Procedure has completed successfully 
ERROR
Bit
Latches high if any error occurs in block.
 
 
 
Input Registers 
The following registers are used as inputs to the function block. They select the options 
and 
 
EXECUTE
Bit
Block enable – Block cannot 
execute unless this is 
TRUE. 
Rising edge initiates 
TRUE – Block enable 
FALSE – Block disable, set 
all outputs to zero and off 
AXIS
Word
Axis number related to the 
block. 
1 to 16
DATA05W
Addres
s 
Address of the first working 
register. 
Five (5) words of register 
space are used by this 
function. 
Input
Type
Description
Range and state
File: MP2000_IndividualFunctionDocument_RevC 118/168 