TECHNICAL NOTE
(1) Homing Type Option
The following table shows thirteen Homing Type. Please select the best one for the
machine.
TYPE
Name
Method
Note
0
DEC1+C phase pulsed
system
Three step deceleration method with
deceleration limit switch and C phase
pulse.
DEC1 signal: DEC signal
of the servo amplifier.
1
ZERO signaling system Homing method with ZERO signal.
ZERO signal: EXT1
signal of the servo
amplifier.
2
DEC 1+ZERO signaling
system
Three step deceleration method with
deceleration limit switch and ZERO signal
DEC1 signal: DEC signal
of the servo amplifier.
ZERO signal: EXT1
signal of the servo
amplifier.
3
C phase pulsed system Homing method with C phase pulse
11
C phase pulse
Method only with C phase pulse
12
POT & C phase pulse
Method with positive OT signal and C
phase pulse
POT: POT signal of the
servo amplifier.
13
POT
Method only with positive OT signal
POT: POT signal of the
servo amplifier.
This method is not
applicable if repeatability
is required.
14
HOME LS&C phase
pulse
Method with HOME signal and C phase
pulse
HOME: EXT1 signal of
the servo amplifier.
15
HOME LS
Method only with HOME signal
HOME: EXT1 signal of
the servo amplifier.
16
NOT&C phase pulse
Method with reverse OT signal and C
phase pulse
NOT: NOT signal of the
servo amplifier.
17
NOT
Method only with reverse OT signal
NOT: NOT signal of the
servo amplifier.
This method is not
applicable if repeatability
is required.
18
INPUT & C phase pulse Method with INPUT signal and C phase
pulse
INPUT: INPUT signal
19
INPUT
Method only with INPUT signal
INPUT: INPUT signal
This method is not
applicable if
repeatability is required.
File: MP2000_IndividualFunctionDocument_RevC 47/168