16.3 Switching Over the Position Display

16.4 Feed Adjustment

Function

Switch TNC to operating mode MACHINE

Prepare TNC to be switched over to position display

Press ENT to switch to desired position display

ACTL, REF. LAG,

Press soft key

to switch the TNC to the

operating mode EDITING

Check/adjust the machine parameters. (Note down the original values before changing.)

MP

Entry

Function

Original Value

1390

0

Feed precontrol ON
in the automatic operating modes

7290

0

Display step = 1

Switch the position display to LAG (display of servo lag).

Enter the following test program:

e.g. 1 LBL 1

2 x 1 0 0

RO

M

(select a larger traverse range if possible)

3 x 0

F

M

4 CALL LBL 1 REP 10

Run the test program in the operating mode PROGRAM RUN/FULL SEQUENCE.

Adjust the feed at the servo amplifier (tachometer) until the servo lag display is approx. zero for

positioning in both directions.

Repeat adjustment for all axes.

Reset the machine parameters and the position display to the