5201 .o – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 163

Function
MP
A
B
C
D
E
F
Input
AE-6
No.
Bit
Entry Value
Operating mode for
EXT
EXT1
EXT2
EXT3 (PLC)
5030
5030.0*
5030.1*
5030.2*
I05
05
05
-
I08
08
08
-
-
-
-
-
0 =
standard data transfer
1 = blockwise transfer
1
1
1
Transfer speed for PLC coupling
(EXT3)
5040
-
-
0 to 9
0 = 110 Bd
5 = 2400 Bd
1 = 150 Bd
6 = 4800 Bd
2 = 300 Bd
7 = 9600 Bd
3 = 600 Bd
8 = 19200 Bd
4 = 1200 Bd
9 = 38400 Bd
7
Control characters for
"Blockwise Transfer"
ASCII character for beginning of
program
EXT1
EXT2
EXT3 (PLC)
(STX)
5200.0*
5200.1*
5200.2*
05
05
-
08
08
-
0 to 127
0
0
0
ASCII character for end of
program
EXT1
EXT2
EXT3 (PLC)
(ETX)
5201.0*
5201.1*
5201.2*
05
05
-
08
08
-
0 to 127
0
0
0
ASCII character for file type (for
data transfer)
EXT1
EXT2
EXT3 (PLC)
5202.0*
5202.1*
5202.2*
05
05
-
08
08
-
0 to 127
0
0
0
ASCII character for input code
EXT1
EXT2
EXT3 (PLC)
(E)
5203.0*
5203.1*
5203.2*
05
05
-
08
08
-
0 to 127
0
0
0
* accessible via code number 123
08.05.95
10.2
32