Positioning – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 141

Function
MP
A
B
C
D E
F
Input
AE-6
No.
Bit
Entry Value
Rapid traverse
X
Y
Z
IV
V
1010.0
1010.1
1010.2
1010.3
1010.4
linear axis:
10 to 30 000 [mm/min]
rotary axis:
10 to 30 000 [°/min]
10000
10000
10000
10000
10000
Manual feed
X
Y
Z
IV
V
1020.0
1020.1
1020.2
1020.3
1020.4
linear axis:
10 to 30 000 [mm/min]
rotary axis:
10 to 30 000 [°/min]
10000
10000
10000
10000
10000
Positioning window
X
Y
Z
IV
V
1030.0
1030.1
1030.2
1030.3
1030.4
linear axis:
0.0001 to 2.0000 [mm]
rotary axis:
0.0001 to 2.0000 [°]
0.05
0.05
0.05
0.05
0.05
Polarity of the nominal voltage with
positive traverse direction
X
Y
Z
IV
V
1040
0
1
2
3
4
0 =
positive
+1 =
X axis negative
+2 =
Y axis negative
+4 =
Z axis negative
+8 =
IV. axis negative
+16 = V. axis negative
% 00000
Analogue voltage for rapid traverse
X
Y
Z
IV
V
1050.0
1050.1
1050.2
1050.3
1050.4
4.5 to 9 [V]
9
9
9
9
9
16.01.95
10.2
10