beautypg.com

HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 130

background image

Code Numbers

123

MACHINE PARAMETER EDITING FOR END USERS (marked by *)

75368

OFFSET ADJUSTMENT

79513

DISPLAY OF VOLTAGE AND TEMPERATURE

86357

REMOVE EDIT/ERASE PROTECTION

95148

MP MODE

105296

COMPENSATION VALUE LIST

531210

RESETTING M 1000 TO M 2000 AND BYTES 0 - 127

620159

DOWNLOADING RUN-IN PROGRAM VIA INTERFACE

807667

PLC MODE

688379

INTERNAL OSCILLOSCOPE

Machine Parameters

The following list contains the machine parameters of all software versions.
Since, however, certain machine parameters are only valid for a certain software version
or from a certain version on, the list contains columns with symbols for differentiation.

Explanation of the Symbols:

‹

= This machine parameter or entry value is valid for all software versions of this control model.

04

= This machine parameter has been introduced with a certain software version

(e.g. 04 means that the MP has been introduced with the software version 04).

I04

= This machine parameter is inactive.

-

= This machine parameter is not available with this control model.

Explanation of the Columns:

A

= TNC 407 with NC software 243 07* -- (without digitizing)

B

= TNC 415 with NC software 243 05* -- and 259 91* -- (without digitizing)

C

= TNC 407 with NC software 243 02* -- (with digitizing)

D

= TNC 415 with NC software 259 96* -- and 259 97* -- (with digitizing)

E

= TNC 407 with NC software 243 03* --(equivalent to TNC 415B/425 software)

F

= TNC 415 with NC software 280 58* -- (special software)

AE-6 = entry values for HEIDENHAIN test unit

RH
1.0 TNC 407/415

Machine Parameters

Overview

16.01.95

10.1