HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 130

Code Numbers
123
MACHINE PARAMETER EDITING FOR END USERS (marked by *)
75368
OFFSET ADJUSTMENT
79513
DISPLAY OF VOLTAGE AND TEMPERATURE
86357
REMOVE EDIT/ERASE PROTECTION
95148
MP MODE
105296
COMPENSATION VALUE LIST
531210
RESETTING M 1000 TO M 2000 AND BYTES 0 - 127
620159
DOWNLOADING RUN-IN PROGRAM VIA INTERFACE
807667
PLC MODE
688379
INTERNAL OSCILLOSCOPE
Machine Parameters
The following list contains the machine parameters of all software versions.
Since, however, certain machine parameters are only valid for a certain software version
or from a certain version on, the list contains columns with symbols for differentiation.
Explanation of the Symbols:
= This machine parameter or entry value is valid for all software versions of this control model.
04
= This machine parameter has been introduced with a certain software version
(e.g. 04 means that the MP has been introduced with the software version 04).
I04
= This machine parameter is inactive.
-
= This machine parameter is not available with this control model.
Explanation of the Columns:
A
= TNC 407 with NC software 243 07* -- (without digitizing)
B
= TNC 415 with NC software 243 05* -- and 259 91* -- (without digitizing)
C
= TNC 407 with NC software 243 02* -- (with digitizing)
D
= TNC 415 with NC software 259 96* -- and 259 97* -- (with digitizing)
E
= TNC 407 with NC software 243 03* --(equivalent to TNC 415B/425 software)
F
= TNC 415 with NC software 280 58* -- (special software)
AE-6 = entry values for HEIDENHAIN test unit
16.01.95
10.1