14.2 Interface Configuration and Allocation of the Operating

Modes

In

addition to the main operating modes the TNC features auxiliary modes or MOD-functions which permit

additional displays and settings.

After pressing MOD in the operating modes EDIT PROGRAM and TEST RUN the following functions can

be selected via soft key:

SETUP

METER

The MOD function for the settings of the data interfaces is selected with the soft key RS 232

422 SETUP

and displayed on the screen:

Note:
With the machine parameter MP5000
interfaces can be disabled. If the entry

value is 0, no interface is disabled.

On the right half of the screen the interface

232C (V.24) is configured, on the left half the interface

RS

(V.ll). On the left side (lower part of the screen) the operating modes PROGRAMMING AND

EDITING, PROGRAM RUN/FULL SEQUENCE and TEST RUN can be allocated to either

232 or RS 422.

(If the MOD function RS 232 422 SETUP is called in the PLC editor or the machine parameter editor,

the editor can be allocated to either RS 232 or RS 422.)

On the right side (lower part of the screen) the user can determine via PRINT and PRINT TEST whether

outputs with FN 15 and digitized positions are to be output via one of the interfaces or into a file in the

memory of the control:

232 means:

RS 422 means:

means:

Data are output via the data interface RS 232.
Data are output via the data interface RS 422.
Data are filed in the TNC.

With the arrow keys

the desired settings

(operating mode, Baud rate and interface allocation) may be selected and set according to your requirements

by pressing

Exit the MOD function RS

422 SETUP by pressing the soft key END