Integrated plc – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 154

Integral PLC
Function
MP
A
B
C
D
E
F
Input
AE-6
No.
Bit
Entry Value
PLC program from RAM or EPROM
4010
+0 = EPROM
+1 = RAM
0
Automatic lubrication
X
Y
Z
IV
V
4060.0
4060.1
4060.2
4060.3
4060.4
0 to 65 535 [65 536 µm]
100
200
300
400
0
Maximum change of the
temperature compensation per PLC
scan in the PLC words W576 - W584
4070
-
-
03
03
0.0001 to 0.0005 [mm]
0.0001
16.01.95
10.2
23