beautypg.com

Spindle control – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 149

background image

Spindle

Function

MP

A

B

C

D E

F

Input

AE-6

No.

Bit

Entry Value

Output of the spindle speed

3010

Š Š Š Š Š Š 0 =

spindle speed not output

6

coded

1 =

only if speed changes

2 =

with every TOOL CALL

analogue

3 =

gear switching signal only if gear range
changes

4 =

gear switching signal with every
TOOL CALL

5 =

no gear switching signal

regulated spindle for orientation

6 =

gear switching signal only if gear range
changes

7 =

gear switching signal with every
TOOL CALL

8 =

no gear switching signal

Output of an analogue voltage at
the analogue output of the spindle
(only if MP3010 < 3)

3011

-
-

-
-

-
-

-
-

-
-

-
-

-
-

-
-

Š

Š

Š

-

Š

Š

Š

Š

0 =

no function

1 =

voltage is proportional to the current feed
rate

2 =

voltage defined via PLC (module 9130)

3 =

voltage defined via M-function
(M200 - M204)

0

Feed rate that corresponds to an
analogue voltage of 10V
(only if MP3011 = 1)

3012

-

-

-

-

Š Š 0 to 300 000 [mm/min]

0

RH
1.0 TNC 407/415

Machine Parameters

MP 3010 - MP 3012

08.05.95

10.2

18