4 machine parameters for the data interfaces, Heidenhain – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 69

HEIDENHAIN
SERVICE MANUAL TNC
Issue:
01.09.19958
Page 58
14.4 Machine Parameters for the Data Interfaces
The detailed functions of the machine parameters are explained in the TNC Manual for Machine Tool
Manufacturers and in the information on the data interface
In the operating modes
ME, FE1 and FE2, the interface parameters are fixed. In the operating modes
and
EXT2, the interface parameters may be determined via machine parameters
machine parameters for the data interfaces are user parameters, i.e. they can be selected with the
code number 123.
14.4.1 Machine Parameters for the “Standard Interface”
(e.g. for ME 101, printer)
MP for
MP for
Entry Values
Function
168
7 data bits, transfer stop by DC3, parity bit (even
parity), 1 stop bit
0
Standard data interface
3
Control character for end of program = ETX
The data format and the type of transfer stop must be set at the printer according to the values
of MP5020.0 and MP5020.1.
MP for
MP for EXT2
Entry Values
Function
168
7 data bits, transfer stop by DC3, parity bit (even
parity),
1 stop bit
Blockwise Transfer
Control character for program start = STX
Control character for end of program = ETX
1. ASCII character for data input =
(e.g. H =
NC program in HEIDENHAIN plain language)
2. ASCII character for data input = E
1. ASCII character for data output =
(e.g. H = NC
program in HEIDENHAIN plain language)
65”
2. ASCII character for data output = A
ASCII character for start of command block = SOH
ASCII character for end of command block = ETB
ASCII character for positive acknowledgement = ACK
212’
ASCII character for negative acknowledgement = NAK
ASCII character for end of transfer = EOT
1) ASCII characters are only valid for the transfer of NC programs.
2) If these machine parameters are programmed with 0, the standard values apply.
14.4.2 Machine Parameters for “Blockwise Transfer”
(e.g. for FE
personal computer with HEIDENHAIN data
transfer software)