HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 167

Tool Calibration with TT 110
Function
MP
A
B
C
D
E
F
Input
AE-6
No.
Bit
Entry Value
Tool calibration cycles
6500
-
-
-
-
-
0 = cycles inhibited
1 = cycles enabled
0
Probing direction for tool
calibration
6505
-
-
-
-
-
0 = pos. probing direction in the angular
reference axis (0° axis)
1 =
pos. probing direction in the +90° axis
2 =
neg. probing direction in the angular
reference axis (0° axis)
3 = neg. probing direction in the +90° axis
0
Calculation of probing feed rate
6507
-
-
-
-
-
0 = calculation of probing feed with constant
tolerance
1 =
calculation of probing feed with variable
tolerance
2 =
constant probing feed
0
Maximum permissible measuring
error when calibrating with a rotating
tool
6510
-
-
-
-
-
0.002 to 0.999 [mm]
0.005
Probing feed rate
when calibrating with a non-rotating tool
6520
-
-
-
-
-
10 to 3 000 [mm/min]
10
Distance between lower edge of
tool and upper edge of stylus
for tool radius calibration
6530
-
-
-
-
-
0.001 to 99.9999 [mm]
10
Diameter or edge length of the
TT 110 stylus
6531
-
-
-
-
-
0.001 to 99 999.9999 [mm]
10
16.01.95
10.2
36