background image

Tool Calibration with TT 110

Function

MP

A

B

C

D

E

F

Input

AE-6

No.

Bit

Entry Value

Tool calibration cycles

6500

-

-

-

-

-

Š 0 = cycles inhibited

1 = cycles enabled

0

Probing direction for tool
calibration

6505

-

-

-

-

-

Š

0 = pos. probing direction in the angular

reference axis (0° axis)

1 =

pos. probing direction in the +90° axis

2 =

neg. probing direction in the angular
reference axis (0° axis)

3 = neg. probing direction in the +90° axis

0

Calculation of probing feed rate

6507

-

-

-

-

-

Š

0 = calculation of probing feed with constant

tolerance

1 =

calculation of probing feed with variable
tolerance

2 =

constant probing feed

0

Maximum permissible measuring
error
when calibrating with a rotating
tool

6510

-

-

-

-

-

Š 0.002 to 0.999 [mm]

0.005

Probing feed rate
when calibrating with a non-rotating tool

6520

-

-

-

-

-

Š 10 to 3 000 [mm/min]

10

Distance between lower edge of
tool and upper edge of stylus
for tool radius calibration

6530

-

-

-

-

-

Š 0.001 to 99.9999 [mm]

10

Diameter or edge length of the
TT 110 stylus

6531

-

-

-

-

-

Š 0.001 to 99 999.9999 [mm]

10

RH
1.0 TNC 407/415

Machine Parameters

MP 6500 - MP 6531

16.01.95

10.2