01.09.1995
Page 59
14.5. Error Messages
14.5.1 Error Messages at the TNC in the ME-Mode
WRONG OPERATING MODE
The wrong operating mode no operating mode was selected on the external data medium
WRONG PROGRAM DATA
Wrong program data have been detected during data transfer. The control attempted
three times to read the data from the magnetic tape before interrupting the process.
DATA MEDIUM MISSING
No cassette has been inserted into the drive.
DATA MEDIUM EMPTY
No programs are stored on the data medium (cassette).
DATA MEDIUM WRITE-PROTECTED
The write-enable plug on the cassette is missing
PROGRAM INCOMPLETE
I
Data transfer was interrupted before the program was transferred completely.
EXT. INPUT/OUTPUT NOT READY
The DSR-signal is missing at the TNC.
ME not connected
Defective or wrong transfer cable
Wrong interface assignment
ME: TAPE END