beautypg.com

Axis double, Incorrect, Point inaccessible – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 64: Exceeded, Cycl-parameter incorrect, Plane wrongly defined, Time limit exceeded

background image

31-O

Kundendienst

SERVICE MANUAL TNC

01.09.1995

Page

53.1

RANGE EXCEEDED

The range has been exceeded during scanning,

a part of the

is outside

the range.

CYCL-PARAMETER INCORRECT

The programmed travel or the distance between lines or points is negative or larger
than 56 535 mm (only possible via Q-parameter programming)

TOUCH POINT INACCESSIBLE

The stylus was deflected before the range was reached during approach.

In the cycle CONTOUR LINES, the stylus was not deflected within the probing range.

STYLUS ALREADY IN CONTACT

The stylus is not at rest, although it is not touching the contour,

PLANE WRONGLY DEFINED

One of the coordinates of the starting point in the cycle CONTOUR LINES is identical

with the touch probe axis.

START POSITION INCORRECT

The starting point coordinate that is identical to the starting probe axis, is beyond the range

AXIS DOUBLE PROGRAMMED

The same axis has been programmed for both starting point coordinates in the cycle

CONTOUR LINES.

TIME LIMIT EXCEEDED

In the scanning cycle CONTOUR LINES the first point of the scanned line was not reached

within the programmed time limit.