beautypg.com

HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 160

background image

Function

MP

A

B

C

D

E

F

Input

AE-6

No.

Bit

Entry Value

PLC: setting a number
(readable with module 9032)

4231.0

...

4231.31

-

...

-

-

...

-

06

...

06

06

...

06

Š

...

Š

Š

...

Š

-99 999.9999 to +99 999.9999 [mm]

0

...

0

PLC: setting a number

W976

(M2192 ... 2207

W978

(M2208 ... 2223

W980

(M2224 ... 2239

W982

(M3200 ... 3215

W984

(M3216 ... 3231

W986

(M3232 ... 3247

W990

(M3248 ... 3263

4310.0
4310.1
4310.2
4310.3
4310.4
4310.5
4310.6

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

-99 999.9999 to +99 999.9999 [mm]

20480

0
0
0
0
0
0

Adaptation of the data interface
extension (X47)

4410

1)

1)

03

03

-

-

0 =

no analogue inputs

1 =

analogue inputs on 1. PL

2 =

analogue inputs on 2. PL

4410

0

1

1)

1)

03

03

Š

Š

+0 = no analogue inputs activated on

1. extension

+1 = analogue inputs on 1. extension (PA 100

or analogue inputs activated on PL 410)

+0 = no analogue inputs activated on

2. extension

+2 = analogue inputs on 2. extension (PA 100

or analogue inputs activated on PL 410)

0

1) MP without function; therefore, do not enter 0.

RH
1.0 TNC 407/415

Machine Parameters

MP 4231.0 - MP 4410

16.01.95

10.2

29