Measurement with, Probe system – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 165

3D-Touch Probe (General Parameters)
Function MP A B C D
E F Input AE-6
No. Bit Entry Value
Selection of touch trigger probe 6010*
0 = transmission via cable (TS 120)
1 = infrared transmission (TS 510)
0
Probing feed rate 6120*
10 to 3 000 [mm/min] 80
Maximum measuring range 6130*
04 04
0.001 to 99 999.9999 [mm] 1
Safety clearance over measuring
point for automatic measurement
6140*
0.001 to 99 999.9999 [mm] 1
Rapid traverse for probe cycle 6150*
10 to 10 000 [mm/min] 2000
M-function for rotating the
spindle by 180° to compensate the
center misalignment of the stylus
6160* - - - -
-1 = oriented spindle stop via NC
0 = function inactive
1 to 88 = number of M-function for oriented
spindle stop via PLC
0
* accessible via code number 123
08.05.95
10.2
34