3D-Touch Probe (General Parameters)

Function MP A B C D

E F Input AE-6

No. Bit Entry Value

Selection of touch trigger probe 6010*

Š

Š

Š

Š

Š

Š 0 = transmission via cable (TS 120)

1 = infrared transmission (TS 510)

0

Probing feed rate 6120*

Š

Š

Š

Š

Š

Š 10 to 3 000 [mm/min] 80

Maximum measuring range 6130*

Š

Š

04 04

Š

Š 0.001 to 99 999.9999 [mm] 1

Safety clearance over measuring
point for automatic measurement

6140*

Š

Š

Š

Š

Š

Š 0.001 to 99 999.9999 [mm] 1

Rapid traverse for probe cycle 6150*

Š

Š

Š

Š

Š

Š 10 to 10 000 [mm/min] 2000

M-function for rotating the
spindle by 180°
to compensate the
center misalignment of the stylus

6160* - - - -

Š

Š -1 = oriented spindle stop via NC

0 = function inactive
1 to 88 = number of M-function for oriented

spindle stop via PLC

0

* accessible via code number 123

RH
1.0 TNC 407/415

Machine Parameters

MP 6010 - MP 6160

08.05.95

10.2