beautypg.com

Data interfaces, 1 operating modes, Heidenhain – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 65

background image

HEIDENHAIN

SERVICE MANUAL TNC

Issue:

01.09.19958

Page

54

14. Data Interfaces

14.1 Operating Modes

For data transfer the TNC

can be switched to the following 5 interface operating modes:

q

ME

For connection of the HEIDENHAIN Magnetic Tape Unit

ME

or other peripheral units

(e.g. printer); data transfer in standard data format; data format data bits, 1 stop bit, even parity)
and Baud rate (2400

adapted to the ME.

For connection of the HEIDENHAIN Floppy Disk Unit

FE 401 or other peripheral units

personal computer with HEIDENHAIN data transfer software). Data are transferred with a special
protocol (blockwise transfer) for data security. Data format 17 data bits, 1 stop bit, even parity) and
the transfer protocol are adapted to the FE 401. the interface mode FE 2 the file names must
be noted down for output of machine parameters, compensation value lists and PLC-programs,

as the directory of the external data medium cannot be displayed by the TNC and the file name

is needed again for data input.

If the floppy disk unit FE 401 is used as an external data medium, no letters are permitted
in program names.

When using the FE 401 the Baud rate at the control must be set to 9600

For connection of the HEIDENHAIN Floppy Disk Unit

FE 4018 (or FE 401, software version

230 626 03 and later) or other peripheral units. Data are transferred with a special protocol
(blockwise transfer) for data security. Data format (7 data bits, 1 stop bit, even parity) and the

transfer protocol are adapted to the FE 401/B. The disk directory is automatically displayed by
the TNC

sequence).

All characters are permitted for program names.

The Baud rate set at the TNC must always match that of the FE 410/B.

Possible Baud rates are 2400, 4800, 9600, 19 200 and 38 400.

To adapt the transfer of data to external units in standard data format and for blockwise transfer.
The interfaces for data transfer are adapted via machine parameters.

Any Baud rate may be selected.

Peripheral units for the EXT operating mode are:

Tape punching units and punched tape readers
Printers or matrix printers for graphic printouts
Mass storage media or programming stations for “Blockwise Transfer”
Programming stations and personal computers for external programming

The Baud rate set at the TNC must always match that of the peripheral unit.

Possible Baud rates: 1 to 38 400.