HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 151

Function
MP
A
B
C
D E
F
Input
AE-6
No.
Bit
Entry Value
Axis standstill, if only a spindle
speed is output during a TOOL CALL
3030
0 = axis standstill
1 =
no axis standstill
0
Programming the spindle speed
S = 0
(if MP3240.1
≠
0)
3120
0
→
S = 0 permitted
1
→
S = 0 not permitted
0
Polarity of S-analogue voltage
3130
0 = M03: positive voltage
M04: negative voltage
1 =
M03. negative voltage
M04: positive voltage
2 =
M03 / M04: positive voltage
3 =
M03 / M04: negative voltage
0
Counting direction of the spindle
encoder
3140
0 = positive
1 = negative
0
S-analogue voltage with nominal
speed
gear range
gear range
gear range
gear range
gear range
gear range
gear range
gear range
1
2
3
4
5
6
7
8
3210.0
3210.1
3210.2
3210.3
3210.4
3210.5
3210.6
3210.7
0 to 9.999 [V]
9
9
9
9
9
9
9
9
Controlled range for S-analogue
output
Max. S-analogue voltage that can be output
Min. S-analogue voltage that can be output
Jog voltage for gear change
(markers for direction of rotation:
M2490 / M2491)
3240.0
3240.1
3240.2
-
-
-
-
-
-
0 to 9.999 [V]
0
0.1
Limit with S-override
max.
min.
3310.0
3310.1
0 to 150 [%]
150
0
16.01.95
10.2
20