beautypg.com

HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 126

background image

SERVICE MANUAL TNC

Issue:

01.09.1995

Page

106

Loosen the screws and remove the PLC

board

4820 6075

Loosen

screws

The new PLC l/O board is mounted in reverse order:

Mount the PLC

board to the logic unit.

-Connect the PLC I/O board to the processor board.
Engage the connectors.
-Switch on the main switch.

Exchange is now finished,

Send and store the boards only in the

original packaging that protects them from acquiring

static charge. Never use conventional plastics to wrap the boards in.