HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 53

83292 86 31-o
SERVICE MANUAL TNC
Issue:
01.09.1995
Page 46
F l a n g e S o c k e t
I Unit
X2 Keyboard
Checking the Potentiometers of the TNC Operating Panel
If an ohmmeter is connected to the pins, the following resistances can be measured (use a measuring adaptor,
if available):
Potentiometer
Flange Socket X2 of Measured Value
Keyboard Unit
PIN
PIN
Position
Position
0
150
Feed Override Pot
36
35
9.7 k
4.7 k
37
35
4.7 k
9.7 k
Spindle Override Pot
36
34
9.7 k
4.7 k
37
34
4.7 k
9.7 k
If a measuring adaptor is available, connect this adaptor between the logic unit and the keyboard unit.
Now the wiper voltages of the potentiometers can be measured at the above pins (values:
0 to 4.95