Adaptation of the data interface – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 161

Adaptation of the Data Interface
Function
MP
A
B
C
D
E
F
Input
AE-6
No.
Bit
Entry Value
Inhibiting a data interface
5000
0 =
no interface inhibited
1 =
RS-232 inhibited
2 =
RS-422 inhibited
0
Control characters for
"Blockwise Transfer"
Character for beginning and end of pro-
gram; the character of end of program is
also valid for the standard data interface
5010.0*
I05 I08
-
-
-
-
0 to 32 382
515
ASCII character for data input
5010.1*
I05 I08
-
-
-
-
0 to 32 382
0
ASCII character for data output
5010.2*
I05 I08
-
-
-
-
0 to 32 382
0
ASCII character for beginning
and end of command block
5010.3*
I05 I08
-
-
-
-
0 to 32 382
0
ASCII character for pos. and neg.
acknowledgement
5010.4*
I05 I08
-
-
-
-
0 to 32 382
0
ASCII character for end of data
transfer
5010.5*
I05 I08
-
-
-
-
0 to 32 382
0
* accessible via code number 123
08.05.95
10.2