beautypg.com

Adaptation of the data interface – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 161

background image

Adaptation of the Data Interface

Function

MP

A

B

C

D

E

F

Input

AE-6

No.

Bit

Entry Value

Inhibiting a data interface

5000

0 =

no interface inhibited

1 =

RS-232 inhibited

2 =

RS-422 inhibited

0

Control characters for
"Blockwise Transfer"
Character for beginning and end of pro-
gram; the character of end of program is
also valid for the standard data interface

5010.0*

I05 I08

-

-

-

-

0 to 32 382

515

ASCII character for data input

5010.1*

I05 I08

-

-

-

-

0 to 32 382

0

ASCII character for data output

5010.2*

I05 I08

-

-

-

-

0 to 32 382

0

ASCII character for beginning
and end of command block

5010.3*

I05 I08

-

-

-

-

0 to 32 382

0

ASCII character for pos. and neg.
acknowledgement

5010.4*

I05 I08

-

-

-

-

0 to 32 382

0

ASCII character for end of data
transfer

5010.5*

I05 I08

-

-

-

-

0 to 32 382

0

* accessible via code number 123

RH
1.0 TNC 407/415

Machine Parameters

MP 5000 - MP 5010.5

08.05.95

10.2

30