Function

MP

A

B

C

D

E

F

Input

AE-6

No.

Bit

Entry Value

Data format and transfer stop
operating mode EXT
operating mode EXT1
operating mode EXT2
operating mode EXT3 (PLC)

5020.0*
5020.1*
5020.2*

I05

05
05

-

I08

08
08

-

-

Š

Š

Š

-

Š

Š

Š

-

Š

Š

Š

-

Š

Š

Š

0 to 255

168
168
168

7 or 8 data bits

0

+0 =

7 data bits, bit 8 = parity

+1 =

8 data bits, bit 8 = 0, bit 9 = parity

Block check character

1

+0 =

BCC may be any character

+2 =

control character not BCC

Transfer stop by RTS

2

+0 =

inactive

+4 =

active

Transfer stop by DC3

3

+0 =

inactive

+8 =

active

Character parity even/odd

4

+0 =

even

+16 =

odd

Character parity on/off

5

+0 =

off

+32 =

on

Number of stop bits

6
7

+64 =

bit 6 = 1

+128 = bit 7 = 1

bit 6

bit 7

0

1

= 1½ stop bits

1

0

= 2 stop bits

0

1

= 1 stop bit

1

1

= 1 stop bit

* accessible via code number 123

RH
1.0 TNC 407/415

Machine Parameters

MP 5020.0 - MP 5020.2

16.01.95

10.2

31