beautypg.com

HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 114

background image

SERVICE MANUAL TNC

Issue:

01.09.1995

Page 94

Loosen the 4 mounting screws on the logic unit

6075

Remove the old logic unit and insert the new one.

19.23 Mounting of the Logic Unit

The logic unit is mounted in the reverse order that is was dismounted:
a) Insert the logic unit and secure it.

Engage connectors.

Observe that no connectors are switched!

Switch on the main switch.

Read in the machine tool data that have been backed up before the exchange

(machine parameters, PLC program, NC programs and tables).

Enter preset values and supplementary operating modes from the table in

section 19.1.5

(before ref. mark traverse).

Offset adjustment with code number (see section 16.5).

Exchange is now finished