background image

31-O

SERVICE MANUAL TNC

issue:

01.09.1995

Page 34

8.3

Power Supply of the NC Part

The power supply line for the NC is connected to the terminals of X31.

The different voltages for the LE are transformed from the voltage fed

in the POWER SUPPLY

assembly. (see block diagram, sec.

The input and output voltages are displayed by

The states of the individual voltages are only displayed

approximately by the

The exact values must be measured, and the measured values must correspond

to the following table:

output

+ 5.2

+ 5.18

+

12

+ 11.4

+ 15

+ 14.4

- 1 5 v

-15

1 4 . 4

u

+ 4.5

+ 3.7

+ 12.3

+ 12

+ 4.75

+

5.22

+ 12.6

+ 15.6

1 5 . 6

+ 12.6

+ 5.25

2.5

0.15

0.3

0.15

20

1.5

0.3

1) + 12 V BE is not required for TNC

2) + 5 V 1 is a potential-free voltage.

NOTE:

Always switch off the main switch before engaging or disengaging any connectors,
The power supply unit does not function during free run (basic load is required).