13.2 Error Messages

TOUCH

POINT INACCESSIBLE

After the start of a probing function, the scanning point was not reached within the

measuring range defined in the machine parameter MP6130.

EXCHANGE TOUCH PROBE BATTERY

The battery voltage of the touch probe system with infrared transmission is below the
minimum value.

STYLUS ALREADY IN CONTACT

The stylus was already deflected when the probing function was started.

PROBE SYSTEM NOT READY

The infrared transmission between the “Touch Probe” and the “Transmitter/Receiver

Unit” is faulty (e.g. caused by contamination) or interrupted. The two windows of the

touch probe system must be oriented to the transmitter/receiver unit.
The battery is dead.

13.2.2

Error Messages during Digitizing of

WRONG AXIS PROGRAMMED

The touch probe axis in the scanning cycle RANGE is not identical to the calibrated
touch probe axis.

FAULTY RANGE DATA

A MIN coordinate value in the scanning cycle RANGE is equal to or larger than the
corresponding MAX coordinate value.

One or more coordinates are beyond the limit switch range of the scanning cycle RANGE.

A scanning cycle RANGE was already defined when the scanning cycles MEANDER or

CONTOUR LINES were called.

MIRRORING NOT PERMITTED

ROTATION NOT

SCALING FACTOR NOT

Mirroring, rotation or scaling factor were active when the scanning cycles RANGE,
MEANDER or CONTOUR LINES were called.