Function
MP
A
B
C
D
E
F
Input
AE-6
No.
Bit
Entry Value
Cancel status display and
Q-parameters with M02, M30 and
END PGM
7300*
I06 I09
-
-
-
-
0 =
status display and Q-parameters are
not cancelled
1 =
status display and Q-parameters are
cancelled
0
Cancel status display and
Q-parameters
•
cancel status display with M02, M30 and
END PGM
•
cancel Q-parameters when program is
selected
7300
0
1
06
06
09
09
-
-
-
-
+0 = status display is not cancelled
+1 = status display is cancelled
+0 = Q-parameters are cancelled
+2 = Q-parameters are not cancelled
Selective erasing of
•
status data (S)
•
TOOL data (T)
•
Q-parameter values (Q)
7300
0
1
2
-
-
-
-
0 to 7
0
with M02, M30, END PGM
- = data are erased
Graphics display
•
view in three planes
7310*
0
+0 = German standard
+1 = American standard
0
•
rotating the coordinate system in the
working plane
1
+0 = no rotation
+2 = coordinate system rotated by +90°
•
BLK form after datum shift
2
-
-
-
-
+0 = BLK form is not shifted
+4 = BLK form is shifted
•
show cursor position in "view in 3 planes"
3
-
-
-
-
+0 = cursor is not displayed
+8 = cursor is displayed
* accessible via code number 123
16.01.95
10.2
45
end of program
program selection
0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
S Q T
- - -
S Q T
- Q -
S Q T
- - T
S Q T
- Q T
- - -
- - -
- Q -
- Q -
- - T
- - T
- Q T
- Q T