2 overview of all files in the ram, 3 external data output, 2 overview of all files in ram – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 77

SERVICE MANUAL TNC
Issue:
01.09.1995
Page 65
15.2 Overview of All Files in RAM
File File Extension File Selection
Directly via Code Number
NC programs HEIDENHAIN language .H
NC programs
.I
Tool files
Pallet tables .P
Datum tables .D
Text files .A
Machine parameters .MP
Compensation value list
PLC program
Error messages 1. language
Error messages English
Dialogs language
Dialogs English
Text files .A
Additional information on the files and programs is provided by letters in the status field:
E: The file/program has been selected in the PROGRAMMING mode.
S: The file/program has been selected and activated in the TEST RUN mode.
M: The file/program has been selected and activated in either PROGRAM RUN/ FULL SEQUENCE
or in PROGRAM RUN/SINGLE BLOCK.
P: The file/program is protected against erasing and editing.
file/program was programmed in Inch.
W:The file/program was not completely transferred to the external memory and thus is no longer
available.
15.3 External Data Output
Connect the external data medium (ME, FE or other peripheral unit, e.g. personal computer with
HEIDENHAIN data transfer software) to the TNC.
Prepare the external data medium for data transfer:
q
and
at the ME
press
at the FE.
Select the operating mode, the Baud rate and the interface assignment (see sections 14.1
The ME (Magnetic Tape Unit) is not very suitable as an external data medium,
as only one file can be stored on one side of a cassette.