Function MP A
B C
D E F Input AE-6
No. Bit Entry Value
Acceleration X
Y
Z
IV
V
1060.0
1060.1
1060.2
1060.3
1060.4
0.001 to 3.0 [m/s²] 1
1
1
1
1
Radial acceleration 1070
0.0001 to 3.0 [m/s²] 1.5
Integral factor
X
Y
Z
IV
V
1080.0
1080.1
1080.2
1080.3
1080.4
0 to 65 535 0
0
0
0
0
Standstill monitoring
X
Y
Z
IV
V
1110
1110.0
1110.1
1110.2
1110.3
1110.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.001 to 30 [mm]
0.0001 to 30 [mm]
0.1
0.1
0.1
0.1
0.1
0.1
Movement monitoring
X
Y
Z
IV
V
1140
1140.0
1140.1
1140.2
1140.3
1140.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.03 to 10 [V]
Note:
entry value 10
→
monitoring inactive
1
1
1
1
1
1
Time out
to switch off the residual nominal voltage
when the error message "Positioning Error"
is generated
1150
0 to 65 535 [s] 0
Automatic cyclic offset adjustment 1220
0 to 65 535 [s]
0 = no automatic adjustment
1
16.01.95
10.2