SERVICE MANUAL TNC

01.09.1995

62.1

14.5.5 Error Messages during Data Transfer

TRANSFERRED VALUE ERRONEOUS X

A

B
C
D
E
F

K
L

faulty character frame

character overflow
character frame or character overflow
parity error
character frame or parity error
character overflow or parity error
character frame or parity error
receiving-buffer overflow

Incorrect ESC sequence (only in ME-mode)

TRANSFERRED DATA INCORRECT X

A

character frame faulty

D

parity error
control has received the character for “negative acknowledgement”
more than 3 times

N

control has sent the character for “negative acknowledgement”

more

than 3 times

BAUD RATE NOT POSSIBLE

If both data interfaces are activated simultaneously

232 RS

the baud rates of

both

interfaces must be the same.

INTERFACE ALREADY ASSIGNED

A data interface cannot be used for two operating modes

simultaneously (e.g. DNC-mode and

programming at the same time is not possible with one data interface).

EXT. IN-/OUTPUT NOT READY

DSR signal at the TNC missing
Defective or wrong transfer cable

Wrong interface assignment

PROGRAM INCOMPLETE

Data transfer was interrupted before the program was completely loaded