Function
MP
A
B
C
D
E
F
Input
AE-6
No.
Bit
Entry Value
ASCII character for file type
(for data output)
EXT1
EXT2
EXT3 (PLC)
5204.0*
5204.1*
5204.2*
05
05
-
08
08
-
0 to 127
0
0
0
ASCII character for output code
EXT1
EXT2
EXT3 (PLC)
(A)
5205.0*
5205.1*
5205.2*
05
05
-
08
08
-
0 to 127
0
0
0
ASCII character for beginning of
command block
EXT1
EXT2
EXT3 (PLC)
(SOH)
5206.0*
5206.1*
5206.2*
05
05
-
08
08
-
0 to 127
0
0
0
ASCII character for end of
command block
EXT1
EXT2
EXT3 (PLC)
(ETB)
5207.0*
5207.1*
5207.2*
05
05
-
08
08
-
0 to 127
0
0
0
ASCII character for positive
acknowledgement
EXT1
EXT2
EXT3 (PLC)
(ACK)
5208.0*
5208.1*
5208.2*
05
05
-
08
08
-
0 to 127
0
0
0
ASCII character for negative
acknowledgement
EXT1
EXT2
EXT3 (PLC)
(NAK)
5209.0*
5209.1*
5209.2*
05
05
-
08
08
-
0 to 127
0
0
0
ASCII character for end of
transfer
EXT1
EXT2
EXT3 (PLC)
(EOT)
5210.0*
5210.1*
5210.2*
05
05
-
08
08
-
0 to 127
0
0
0
* accessible via code number 123
16.01.95
10.2
33