beautypg.com

HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 132

background image

Function

MP

A

B

C

D E

F

Input

AE-6

No.

Bit

Entry Value

Axes with encoder

X
Y
Z
IV
V

10

0
1
2
3
4

Š Š Š Š Š Š 0 =

no encoder

+1 =

X axis with encoder

+2 =

Y axis with encoder

+4 =

Z axis with encoder

+8 =

IV. axis with encoder

+16 = V. axis with encoder

% 11111

(31)

Encoder monitoring
Absolute position with distance-coded
reference marks

X
Y
Z
IV
V
S

30

0
1
2
3
4
5

Š Š Š Š Š Š 0 =

no axis monitored

+1 =

X axis monitored

+2 =

Y axis monitored

+4 =

Z axis monitored

+8 =

IV. axis monitored

+16 = V. axis monitored
+32 = S axis monitored

% 111111

(63)

Signal amplitude

X
Y
Z
IV
V
S

31

0
1
2
3
4
5

Š Š Š Š Š Š 0 =

no axis monitored

+1 =

X axis monitored

+2 =

Y axis monitored

+4 =

Z axis monitored

+8 =

IV. axis monitored

+16 = V. axis monitored
+32 = S axis monitored

% 111111

(63)

Edge separation

X
Y
Z
IV
V
S

32

0
1
2
3
4
5

Š Š Š Š Š Š 0 =

no axis monitored

+1 =

X axis monitored

+2 =

Y axis monitored

+4 =

Z axis monitored

+8 =

IV. axis monitored

+16 = V. axis monitored
+32 = S axis monitored

% 111111

(63)

RH
1.0 TNC 407/415

Machine Parameters

MP 10 - MP 32

16.01.95

10.2