beautypg.com

HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 15

background image

31-O

SERVICE MANUAL TNC 4071415

01.09.1995

Kundendienst

9

A Signal amplitude error

B Signal frequency error

C Error with distance-coded scale

Y CPU number

1 main processor

2 geometry processor

3 CLP processor

Possible

causes:

Encoder not connected
Cable damaged
Glass scale contaminated or damaged

Scanning head defective

Encoder monitoring system defective

Wrong reference mark spacing entered with distance-coded
linear encoders (counting error caused by the measuring
system or the LOGIC UNIT)

Temoerature inside the LOGIC UNIT has exceeded 70” C

Emergency-stop test

2. Emergency-stop test

1.

3. Emergency-stop test

Error during the test routine for the output “Control Ready for
Operation” (see section 17.4)

This error message is only generated if the marker 2815 is set
without additional marker

Marke 2924

and marker 2815 set

Marke 3023

Instead of “PLC: ERROR 00 to 99” another dialog may be displayed with customized