Chapter 2 Configuring the Library

34

PLS200 Library Installation and Operation

Setting the SCSI IDs

NOTE: The SCSI IDs shown are factory default settings. The default settings are the

correct IDs for use with the Profile system. Unless the SCSI IDs in the Profile
system have been altered, you should not need to change the library’s SCSI
ID settings. If one of the drive carrier slots contains a drive blank, the library
displays a B (for blank) instead of a SCSI ID.

Default SCSI IDs are assigned at the factory for the library and each tape drive.
Drive blanks are assigned B (for blank). This section describes how to view the
default settings and change them if necessary.

Important

The library and tape drives must each have a unique SCSI ID

within each SCSI bus. Because you have multiple SCSI buses, the library
does not check for duplicate SCSI IDs. It is your responsibility to make sure
you do not assign duplicate SCSI IDs within a SCSI bus.

To view or change SCSI IDs:

1. From the Configuration Menu, make sure the screen arrow is pointing to Set

SCSI IDs and press

. The following screen appears, where Dn

indicates a tape drive and LIB indicates the library:

2. To set the SCSI ID for the bottom tape drive (D4), press

or

until the

screen displays the SCSI ID you want. SCSI IDs for wide SCSI
configurations range from 0 to 15.

Enter

S C S

I

D 4

D 3

D 2

D 1

L

I

B

I D s

:

0 2

0 1

0 2

0 1

0 5