beautypg.com

Power power cord requirements, Scsi terminator specifications – Grass Valley PLS200 User Manual

Page 142

background image

Appendix A Specifications

120

PLS200 Library Installation and Operation

Power

Power Cord Requirements

The library is shipped with four 18 AWG, 3-conductor AC power cords for use
in North America, the United Kingdom, Europe, and Australia. Each power
cord has a molded IEC type CEE-22 female connector at one end. At the other
end is a molded attachment plug of the proper type, rating, and safety approval
for the intended country. The North American power cord is UL Listed and
CSA Certified.

SCSI Terminator Specifications

The SCSI terminator must match the PLS200 SCSI bus configuration (wide
differential). In addition, all termination must be external. Do not use internal
terminators to terminate the library or the tape drives.

To ensure proper performance of the library and tape drives, Tektronix
recommends the following external terminator:

• AMP Amplimite 869515-1

Input voltages

Accepts 90 to 259 VAC at 48 to 62 Hz; automatic
input voltage selection

Power consumption
(AC true power)

95 watts minimum; 145 watts maximum. Based on the
AC true power consumption, the library generates
between 325 and 495 BTU/hour.