Appendix b lcd error codes – Grass Valley PLS200 User Manual
Page 146

Appendix B LCD Error Codes
124
PLS200 Library Installation and Operation
13
PUT MECH. FAILURE. The CHM
could not successfully place a
cartridge because of mechanical
problems.
Make sure there is nothing blocking the CHM or the tape
drives. If the error persists, contact your service provider.
14
PICK MECH. FAILURE. The CHM
could not successfully pick a cartridge
because of mechanical problems.
15
NO SRC ELEMENT; NO DEST
ELEMENT. No data cartridge
magazine was installed at the selected
location.
Request a new inventory of the cartridges in the library.
16
17
CHM FULL BEFORE MOVE. There
was a cartridge in the gripper when
the operator powered-on or reset the
library, or before a move operation.
Remove the cartridge and put it back in the cartridge
magazine if you know where it goes.
Make sure the library and tape drives are not being used by
any host, then press
on the operator panel. If the
error persists, contact your service provider.
18
SRC CART INSIDE CTS. The CHM
could not successfully pick a cartridge
because it was still loaded in the tape
drive.
Press the tape drive eject button and wait for the cartridge
to be unloaded.
Error
Description
Corrective Action