beautypg.com

H3C Technologies H3C S7500E Series Switches User Manual

Page 395

background image

13-44

Expires: 00:01:46

# View the BSR information and the locally configured C-RP information in effect on Switch D.

[SwitchD] display pim ipv6 bsr-info

Elected BSR Address: 1003::2

Priority: 20

Hash mask length: 128

State: Elected

Uptime: 00:05:26

Expires: 00:01:45

Candidate BSR Address: 4002::1

Priority: 10

Hash mask length: 128

State: Candidate

Candidate RP: 4002::1(Vlan-interface105)

Priority: 0

HoldTime: 130

Advertisement Interval: 60

Next advertisement scheduled at: 00:00:48

# View the BSR information and the locally configured C-RP information in effect on Switch E.

[SwitchE] display pim ipv6 bsr-info

Elected BSR Address: 1003::2

Priority: 20

Hash mask length: 128

State: Elected

Uptime: 00:01:10

Next BSR message scheduled at: 00:01:48

Candidate BSR Address: 1003::2

Priority: 20

Hash mask length: 128

State: Elected

Candidate RP: 1003::2(Vlan-interface102)

Priority: 0

HoldTime: 130

Advertisement Interval: 60

Next advertisement scheduled at: 00:00:48

To view the RP information discovered on a switch, use the display pim ipv6 rp-info command.

For example:

# View the RP information on Switch A.

[SwitchA] display pim ipv6 rp-info

PIM-SM BSR RP information:

prefix/prefix length: FF0E::101/64

RP: 4002::1

Priority: 0

HoldTime: 130

Uptime: 00:05:19

Expires: 00:02:11

RP: 1003::2

Priority: 0