HoldTime: 150

Uptime: 00:51:45

Expires: 00:02:22

RP: 192.168.9.2

Priority: 0

HoldTime: 150

Uptime: 00:51:45

Expires: 00:02:22

Assume that Host A needs to receive information addressed to the multicast group G

(225.1.1.0). The RP corresponding to the multicast group G is Switch E as a result of hash

calculation, so an RPT will be built between Switch A and Switch E. When the multicast source

S (10.110.5.100/24) registers with the RP, an SPT will be built between Switch D and Switch E.

Upon receiving multicast data, Switch A immediately switches from the RPT to the SPT.

Switches on the RPT path (Switch A and Switch E) have a (*, G) entry, while switches on the

SPT path (Switch A and Switch D) have an (S, G) entry. You can use the display pim

routing-table command to view the PIM routing table information on the switches. For

example:

# View the PIM routing table information on Switch A.

[SwitchA] display pim routing-table

Total 1 (*, G) entry; 1 (S, G) entry

(*, 225.1.1.0)

RP: 192.168.9.2

Protocol: pim-sm, Flag: WC

UpTime: 00:13:46

Upstream interface: Vlan-interface102

Upstream neighbor: 192.168.9.2

RPF prime neighbor: 192.168.9.2

Downstream interface(s) information:

Total number of downstreams: 1

1: Vlan-interface100

Protocol: igmp, UpTime: 00:13:46, Expires: 00:03:06

(10.110.5.100, 225.1.1.0)

RP: 192.168.9.2

Protocol: pim-sm, Flag: SPT ACT

UpTime: 00:00:42

Upstream interface: Vlan-interface101

Upstream neighbor: 192.168.1.2

RPF prime neighbor: 192.168.1.2

Downstream interface(s) information:

Total number of downstreams: 1

1: Vlan-interface100

Protocol: pim-sm, UpTime: 00:00:42, Expires: 00:03:06

The information on Switch B and Switch C is similar to that on Switch A.

# View the PIM routing table information on Switch D.

[SwitchD] display pim routing-table

Total 0 (*, G) entry; 1 (S, G) entry