beautypg.com

H3C Technologies H3C S7500E Series Switches User Manual

Page 338

background image

12-18

To do…

Use the command…

Remarks

Configure the MLD last listener

query interval

last-listener-query-interval

interval

Optional

1 second by default

Configure the MLD other querier

present interval

timer other-querier-present

interval

Optional

By default, the other querier

present interval is determined by

the formula: Other querier present

interval (in seconds) = [ MLD query

interval ] × [ MLD querier’s

robustness variable ] + [ maximum

response delay for MLD general

query ] /2.

Configuring MLD query and response parameters on an interface

Follow these steps to configure MLD query and response parameters on an interface:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter interface view

interface interface-type

interface-number

Configure the MLD querier’s

robustness variable

mld robust-count robust-value

Optional

2 times by default

Configure the startup query

interval

mld startup-query-interval

interval

Optional

By default, the startup query

interval is 1/4 of the “MLD query

interval”.

Configure the startup query count

mld startup-query-count value

Optional

By default, the startup query count

is set to the MLD querier’s

robustness variable.

Configure the MLD query interval

mld timer query interval

Optional

125 seconds by default.

Configure the maximum response

delay for MLD general query

messages

mld max-response-time interval

Optional

10 seconds by default

Configure the MLD last listener

query interval

mld last-listener-query-interval

interval

Optional

1 second by default