beautypg.com

Delta Electronics VFD-M User Manual

Page 92

background image

Chapter 4 Parameters|

Revision May 2008, ME14, SW V3.04

4-57

Application Note:

PLC program execution will be interrupted when values for JOG parameters 15 and 16 are changed.

Pr.79

PLC Forward/Reverse Motion

Settings 00 to 127

Factory Setting: 00

This parameter determines the direction of motion for the multi-speed Pr.17 to Pr.23 and

Master Frequency. The original direction of Master Frequency will become invalid.

Note: A 7-bit binary number is used to program the forward/reverse motion for each of the 8 speed

steps (including Master Frequency). The binary notation for the 7-bit number must be

translated into decimal notation and then entered in Pr.79.

1

2

3

4

5

6

7

Weights

Bit

0=Forward

1=Reverse

Direction of 1st

Pr.17

speed for

Direction of 2nd

Pr.18

speed for

Direction of 3rd

Pr.19

speed for

Direction of 4th

Pr.20

speed for

Direction of 5

Pr.21

th speed for

Direction of 6

Pr.22

th speed for

Direction of 7

Pr.23

th speed for

Example:

1

2

3

4

5

6

7

Weights

Bit

0=Forward

1=Reverse

Forward motion of Pr.17 multi-speed1

Reverse motion of Pr.18 multi-speed2
Forward motion of Pr.19 multi-speed3
Forward motion of Pr.20 multi-speed4
Forward motion of Pr.21 multi-speed5
Reverse motion of Pr.22 multi-speed6
Forward motion of Pr.23 multi-speed7

0

1

0

0

0

1

0

Direction

The setting value=bit7 x 2

6

+bit6 x 2

5

+bit5 x 2

4

+bit4 x 2

3

+bit3 x 2

2

+bit2 x 2

1

+bit1 x 2

0

= 0 x 2

6

+1 x 2

5

+0 x 2

4

+0 x 2

3

+0 x 2

2

+1 x 2

1

+0 x 2

0

= 0+32+0+0+0+2+0+0
= 34