Chapter 4 Parameters|

Revision May 2008, ME14, SW V3.04

4-13

Parameter

Explanation

Settings

Factory

Setting

Customer

Pr.145

Total operation time
(Minutes)

Read Only

Pr.146 Line

start

Lockout

00: Disable
01: Enable

00

Pr.147

Decimal Number of
Accel / Decel Time

00: One decimal
01: Two decimals

00

Pr.148

Number of Motor
Poles

02 to 20

04

Pr.149

Gear Ratio for Simple
Index Function

4 to 1000

200

Pr.150

Index Angle for Simple
Index Function

00.0 to 360.0

180.0

Pr.151

Deceleration Time for
Simple Index Function

0.00 to 100.00 sec

0.00

Pr.152

Skip Frequency Width 0.00 to 400.0Hz

0.00

Pr.153

Bias Frequency Width 0.00 to 400.0Hz

0.00

Pr.154 Reserved

Pr.155

Compensation
Coefficient for Motor
Instability

0.0: Disable
0.1 to 5.0 (recommended setting d2.0)

0.0

Pr.156

Communication
Response Delay Time

0 to 200 (x500us)

0

Pr.157

Communication Mode
Selection

0: Delta ASCII

1: Modbus

1