Rear panel, 2 − names and functions of parts – Teac HS-4000 User Manual
Page 13

TASCAM HS-4000
13
2 − Names and functions of parts
Rear panel
h
ANALOG LINE IN 1–4 connectors
These XLR connectors are balanced analog line inputs.
(1:GND, 2:HOT, 3:COLD)
j
DIGITAL LINE IN 1–2 connectors
Use these balanced XLR connectors (1 and 2) for digital
audio input in AES3-2003/IEC60958-4 (AES/EBU) or
IEC60958-3 (S/PDIF) format.
Sampling frequencies of 88.2 and 96 kHz are transmitted at
double speed.
The built-in sampling rate converter can handle 32–192 kHz.
k
MONITOR ANALOG OUT L/R connectors
These are left and right balanced analog XLR monitoring
output connectors (1: GND, 2: HOT, 3: COLD).
These output monitoring signals (the audio output from the
internal monitoring mixer).
l
RS-232C connector
This is a D-sub 9-pin RS-232C serial control connector.
Use it to connect an external controller.
NOTE
The RS-232C connector will be made functional in a future
firmware version update.
It cannot be used at the same time as the RS-422 connector.
(See “RS–232C page” on page 108.)
;
PARALLEL connector
Connect an external controller, for example, to this 25-pin
D-sub parallel control connector.
z
AC IN connector
Connect the included power cord here.
x
ANALOG LINE OUT 1–4 connectors
These XLR connectors are balanced analog line outputs.
(1:GND, 2:HOT, 3:COLD)
In dual playlist mode, player A outputs from connectors 1
and 2, while player B outputs from connectors 3 and 4.
c
DIGITAL LINE OUT 1/2 connectors
These XLR connectors are balanced outputs for digital audio
in AES3-2003/IEC 60958-4 (AES/EBU) format.
Sampling frequencies of 88.2 and 96 kHz are transmitted at
double speed.
In dual playlist mode, player A outputs from connector 1,
while player B outputs from connector 2.
v
REMOTE connectors
Connect a TASCAM RC-HS32PD remote control (sold
separately) here.
CAUTION
This is not an Ethernet connector (LAN, etc.). Never connect
this to a network using an Ethernet cable.
Doing so could damage this unit or equipment in the
network.
b
RS-422 connector
This is a D-sub 9-pin RS-422 serial control connector.
Use it to connect an external controller, for example.
NOTE
It cannot be used at the same time as the RS-232C
connector. (See “RS–422 page” on page 108.)
n
TIMECODE IN connector
This XLR connector is a balanced input for SMPTE timecode
input.
m
TIMECODE OUT connector
This XLR connector is a balanced output for SMPTE timecode
output.
,
WORD/VIDEO IN connector
This is a BNC-type word clock an video reference signal
input connector. Use it to input a word clock signal (44.1kHz,
48kHz, 48kHz pull-down, 48kHz pull-up, 88.2kHz or 96kHz)
or a video reference signal (NTSC/PAL black burst signal,
HDTV Tri-level signal).
Use the switch to set whether or not to terminate with 75Ω.
.
WORD/VIDEO THRU/WORD OUT connector
This is a BNC-type word clock (through/output) and video
reference signal through/output connector.
Use it to output a word clock signal (through, 44.1kHz,
48kHz, 48kHz pull-down, 48kHz pull-up, 88.2kHz or 96kHz
output) or a video reference signal (IN connector signal
through).
Use the THRU/WORD OUT switch to set the signal output.
/
75Ω OFF/ON and THRU/WORD OUT switch
Use this switch to make the following settings.
o
Whether or not the WORD/VIDEO IN connector has
termination resistance (75Ω)
o
The WORD/VIDEO output THRU/OUT setting (OUT is
only for WORD)
!
ETHERNET connector
Use this Ethernet connector for network connection to
conduct file transfer and external control of this device.
@
GROUND terminal
When using a TASCAM RC-HS32PD remote control (sold
separately), depending on the operating environment, the