Start-up Commands
03/07/03
12-3
8.
Type LO PRO;AC to load the system's fuel
product codes, categories, names, and
pricing data.
A*LO PRO;AC
↵
Product code? 1
↵
Category? 1
↵
Product name? Regular
↵
Minimum price? 0
↵
Maximum price? 0
↵
Taxes? 0
↵
Product code?
↵
A*
9.
Type LO IN;C to load inventory amounts
and reorder levels for fuel products.
NOTE: LO IN automatically enables inventory
tracking. For more information on
inventory tracking, see the Site
Manager's Manual.
A*LO IN
;C
↵
Product? 1
↵
Quantity? 400
Reorder level? 100
A*
10. Type RE PU to reset the pumps to zero. If
you wish to set the quantity and dollar
totalizers maintained by the Site Controller
to the same settings as the mechanical
totalizers on the pump, do a LO PU;C
command.
NOTE:
You may load up to five hoses
per pump. When you enter the
last hose for a particular pump,
press RETURN at the next
hose number prompt to get the
next Pump Number prompt.
A*RE PU
↵
Verify (Y/N)? Y
↵
A*LO PU;C
↵
Pump number? 1
↵
Hose number? 1
↵
Quantity? 5624.8
↵
$amount 3217.95
↵
Hose number?
↵
Pump number? 2
↵
Hose number? 2
↵
Quantity? 2345.9
↵
$amount 6789.10
↵
Hose number?
↵
Pump number?
↵
A*
11. Type LO TA;C to load the system's initial
quantity, product code and reorder level for
each tank (tank inventory).
A*LO TA;C
↵
Tank number? 1
↵
Quantity? 9325
↵
Product code? 1
↵
Reorder level? 2000
↵
Tank number?
↵
A*