background image

CFN Series System

8-10

03/07/03

Okidata 184 Setup

To prepare the Okidata printer for operation with the LINK MC5 terminal and your GASBOY Fuel
Management System, perform the following steps. Install and complete the setup of the printer as
specified in the manufacturer's setup instructions. Then set up the switches as follows:

SW1-1 ON

Parity: Odd

SW1-2 ON

Parity: Without

SW1-3 ON

Data bits: 8

SW1-4 OFF

Protocol: XON/XOFF

SW1-5 ON

Test select: Circuit

SW1-6 ON

Mode select: Print

SW1-7 ON

Busy line selection: DTR - Pin 20

SW1-8 ON

Busy line selection: DTR - Pin 20

SW2
Baud Rate

SW2-1

SW2-2

SW2-3

9600

OFF

ON

ON

2400

OFF

OFF

ON

1200

ON

ON

OFF

300

ON

OFF

OFF

NOTE: Any change made to the baud rate must also be changed on the Link terminal

Communications Setup screen, Aux Baud parameter.

SW2-4 ON

DSR output signal: Active

SW2-5 ON

Buffer threshold: 32 bytes

SW2-6 OFF

Busy signal timing: 1 sec (min.)

SW2-7 ON

DTR signal: Space after power on

SW2-8 OFF

Not used

1.

Turn the printer offline by pressing SELECT. The SELECT light should go off.

2.

Position the print head at the top of the paper and press the TOF SET button.

3.

Put the printer back online by pressing SELECT. The SELECT light should go on.

4.

Press the MODE button until the light next to HSD is lit.

5.

Press the PITCH button until the light next to 17 is lit.

NOTE: Pitch may be set to a lower number (resulting in larger print) if transactions are less

than 80 characters.

SITE CONTROLLER CONFIGURATION CHANGES

Although the system has already been configured and tested at the factory, you may need to
perform some configuration changes to match the site's characteristics. Follow the instructions in
the Site Controller II Configuration Manual to make these changes.

The software for a CFN system with a 3 1/2" disk drive and a hard disk is supplied on the hard
disk and also on a backup 3 1/2" disk. During normal system use, any configuration changes or
command files, etc. that you add to the CFN system are automatically place on the hard disk.
These changes must be copied onto the backup 3 1/2" disk to keep your backup current.